Thank you for this superb 2024 edition! Exhibitor Login
16.01.2018 Wandfluh AG C - Automatisation

Pressure reducing valve manually adjustable

The cartridge valve in the nominal size of U10 controls the manually adjusted output pressure independently of the input pressure and the volume flow. 
Through the 3-way function, overpressures at the output of the valve can be actively relieved against the tank. This guarantees, at all times, a stable pressure on the consumer in the system. The optimised valve design results in very good pressure-volume flow characteristics with simultaneously low hysteresis. The leakage at 20 ml/min is extremely low. 

The valve with the designation MDSPU10 can be operated with input pressures of up to 350 bar and volume flows of up to 20 l/min. As output pressure levels, 80 and 200 bar are available. The external parts of the valve have a high corrosion protection through the use of stainless materials. 

Further details can be found in the 2.2-550 data sheet.